Конденсат на окнах

 

Точка росы

  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • strict warning: Only variables should be assigned by reference in /home/u3761/domains/okna-info.com.ua/sites/all/modules/acidfree/acidfree.module on line 581.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • : Function ereg() is deprecated in /home/u3761/domains/okna-info.com.ua/includes/file.inc on line 646.
  • warning: Parameter 1 to advpoll_voting_binary_form() expected to be a reference, value given in /home/u3761/domains/okna-info.com.ua/includes/form.inc on line 218.
  • strict warning: Only variables should be assigned by reference in /home/u3761/domains/okna-info.com.ua/sites/all/modules/acidfree/acidfree.module on line 581.
Изображение пользователя admin.

Точкой росы при данном давлении называется температура, до которой должен охладиться воздух, чтобы содержащийся в нём водяной пар достиг состояния насыщения и начал конденсироваться в росу.

На приведённой диаграмме представлено максимальное содержание водяного пара в воздухе на уровне моря в зависимости от температуры. Чем выше температура, тем выше равновесное парциальное давление пара.

Точка росы определяется относительной влажностью воздуха. Чем выше относительная влажность, тем точка росы выше и ближе к фактической температуре воздуха. Чем ниже относительная влажность, тем точка росы ниже фактической температуры. Если относительная влажность составляет 100 %, то точка росы совпадает с фактической температурой.

Формула для приблизительного расчёта точки росы в градусах Цельсия:

T_p = \frac {b\ \gamma(T,RH)} {a - \gamma(T,RH)},

где

a = 17.27,
b = 237.7 °C,
ln — натуральный логарифм,
T = температура в градусах Цельсия,
RH = относительная влажность в долях (0 < RH < 1.0),
Tp = точка росы,
\gamma(T,RH) = \frac {a\ T} {b+T} + \ln RH.

Формула обладает погрешностью ±0.4 °C в следующем диапазоне значений:

0 °C < T < 60 °C
0.01 < RH < 1.0
0 °C < Tр < 50 °C

Человек при высоких значениях точки росы чувствует себя некомфортно. В континентальном климате условия с точкой росы между 15 и 20°C доставляют некоторый дискомфорт, а воздух с точкой росы выше 21 °C воспринимается как душный.

ТАБЛИЦА ТОЧКИ РОСЫ

ОТНОСИТЕЛЬНАЯ ВЛАЖНОСТЬ% RH, ТЕМПЕРАТУРА ШАРИКА СУХОГО ТЕРМОМЕТРА, °C

% RH 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25
20 -20 -18 -16 -14 -12 -9.8 -7.7 -5.6 -3.6 -1.5 -0.5
25 -18 -15 -13 -11 -9.1 -6.9 -4.8 -2.7 -0.6 1.5 3.6
30 -15 -13 -11 -8.9 -6.7 -4.5 -2.4 -0.2 1.9 4.1 6.2
35 -14 -11 -9.1 -6.9 -4.7 -2.5 -0.3 1.9 4.1 6.3 8.5
40 -12 -9.7 -7.4 -5.2 -2.9 -0.7 1.5 3.8 6.0 8.2 10.5
45 -10 -8.2 -5.9 -3.6 -1.3 0.9 3.2 5.5 7.7 10.0 12.3
50 -9.1 -6.8 -4.5 -2.2 0.1 2.4 4.7 7.0 9.3 11.6 13.9
55 -7.9 -5.6 -3.3 -0.9 1.4 3.7 6.1 8.4 10.7 13.0 15.3
60 -6.8 -4.4 -2.1 0.3 2.6 5.0 7.3 9.7 12.0 14.4 16.7
65 -5.8 -3.4 -1.0 1.4 3.7 6.1 8.5 10.9 13.2 15.6 18.0
70 -4.8 -2.4 0.0 2.4 4.8 7.2 9.6 12.0 14.4 16.8 19.1
75 -3.9 -1.5 1.0 3.4 5.8 8.2 10.6 13.0 15.4 17.8 20.3
80 -3.0 -0.6 1.9 4.3 6.7 9.2 11.6 14.0 16.4 18.9 21.3
85 -2.2 0.2 2.7 5.1 7.6 10.1 12.5 15.0 17.4 19.9 22.3
90 -1.4 1.0 3.5 6.0 8.4 10.9 13.4 15.8 18.3 20.8 23.2
95 -0.7 1.8 4.3 6.8 9.2 11.7 14.2 16.7 19.2 21.7 24.1
100 0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0

Рекомендуется окрашивать поверхность, если ее температура превышает точку росы на 3°C.
Пример:
Если температура воздуха +21°C , а относительная влажность 65%, то точка росы составляет +14°C . То есть, в данном случае температура окрашиваемой поверхности должна быть не ниже 14+3=17°C

Определение точки росы

Значения точки росы в градусах °C для ряда ситуаций определяют с помощью пращевого психрометра и специальных таблиц. Сначала определяют температуру воздуха, затем влажность, температуру подложки и с помощью таблицы Точки росы определяют температуру, при которой не рекомендуется наносить покрытия на поверхность.

Если вы не можете найти точно ваши показания на пращевом психрометре, то найдите один показатель на одно деление выше по обеим шкалам, как относительной влажности, так и температуры, а другой показатель соответственно на одно деление ниже и интерполируйте необходимое значение между ними.

Конденсат и точка росы
Конденсат
— наиболее распространенная проблема, с которой приходится сталкиваться производителям ПВХ-окон и их потребителям. Новые нормы определили расчетные параметры относительной влажности помещений для определения точки росы и требования к температуре на внутренней поверхности окон ПВХ:
5.9 …Относительную влажность  внутреннего  воздуха для  определения температуры точки росы в местах теплопроводных включений ограждающих конструкций, в углах и оконных откосах, а также зенитных фонарей, следует принимать:
• для помещений жилых зданий, больничных учреждений, диспансеров, амбулаторно-поликлинических учреждений, родильных домов, домов-интернатов для престарелых и инвалидов, общеобразовательных детских школ, детских садов, яслей, яслей-садов (комбинатов) и детских домов — 55%, для помещений кухонь — 60%, для ванных комнат — 65%, для теплых подвалов и подполий с коммуникациями — 75%;
• для теплых чердаков жилых зданий — 55%;
• для помещений общественных зданий (кроме вышеуказанных) — 50%.
5.10 Температура внутренней поверхности конструктивных элементов остекления окон зданий (кроме производственных) должна быть не ниже плюс 3°С, а непрозрачных элементов ПВХ окон — не ниже температуры точки росы при расчетной температуре наружного воздуха в холодный период года, для производственных зданий — не ниже 0°С
Температура на внутренней поверхности профилей напрямую зависит от сопротивления теплопередаче профильной системы. Для примера можно рассмотреть два случая — при наружной температуре —26°С и при —31°С (при внутренней +20°С и относительной влажности 55%). Точка росы при этом будет составлять +10,7°С. Температуры на поверхностях типового переплета (три камеры и ширина около 60 мм) и пя-тикамерного переплета с сопротивлением теплопередаче 0,78м??°С /Вт будут следующими:

Вариант переплета t°С на поверхности переплета при tн=-26С t°С на поверхности переплета при tн=-31°С
Переплет с 0,63м??°С/Вт 11,82°С 9,79°С
Переплет с 0,78м??°С/Вт 13,22°С 12,48°С

Исходя из вышесказанного видно, что в новых нормах по тепловой защите зданий заложена предпосылка к совершенствованию конструкций окон из ПВХ, применяемых в строительной практике. Я уверен в том, что будущее принадлежит новым конструкциям ПВХ окон из многокамерных систем с шириной профилей не менее 70 мм.

Журнал “OKNA.BZ” №3 2004г.